Domestic hot water is provided by large high-efficiency water heaters and storage tank. Plumbing systems include new plumbing fixtures, sanitary waste and vent and potable water to all guestrooms. ![]() Guestroom and suite exhaust is served by central rooftop exhaust fans. The fitness center and basement are served by split-system heat pump units. The buffet seating expansion, entry lobby, casino/hotel connection and corridors are heated and cooled using rooftop gas/electric units. The HVAC system serving the guestrooms and suites is variable refrigerant flow split systems with multiple fan coil units connecting to a common condensing unit. This hotel consists of 150 rooms, buffet expansion, casino concourse, and basement. ![]() Mechanical and plumbing design for a new 5 story hotel, approximately 90,470 SF, at Viejas Casino.